Compatible 10-lead bosch ecG cable

CompatibleBosch One-Piece 10-Lead EKG CableCompatibility:ManufacturerModelBoschEKG 601BurdickEK-10, Elite, Elite II, E-350,E350i,E550, E560, (1st GenerationEclip se LE/LEi, withserial numberstarting with 1051). Burdick #007705,Stress cable with detachableleads007706Fukuda DenshiAlpha 500 / 600, FCP 2201Fukuda MECardisuny al

Featured Products

CompatibleBosch One-Piece 10-Lead EKG Cable

Compatibility:

ManufacturerModel
BoschEKG 601
BurdickEK-10, Elite, Elite II, E-350,E350i,E550, E560, (1st GenerationEclip se LE/LEi, with
serial numberstarting with 1051). Burdick #007705,Stress cable with detachable
leads007706
Fukuda DenshiAlpha 500 / 600, FCP 2201
Fukuda MECardisuny alpha 4.700,Cardisuny alpha 6600 A / 6600 AX
ContecContec All
Nihon
Kohden
Cardiofax6151/6353,Cardiofax EKG-8270/8350/8370/8420/8423/8450/8453
/8820/8823/8830/9130 Cardiofax-Q;

Technical Specifications:
ECG interpretation:Nihon Kohden ECG Analysis Program for Adults and Pediatrics
Computerized measurements:12-lead analysis
ECG analysis frequency:500 samples/second (sps)
Digital sampling rate:2,000 samples/second/channel
Dynamic range:AC Differential ± 5mV, DC offset ±300 mV
Resolution:4.88 μV/LSB @ 500 sps
Frequency response:-3 dB @ 0.01 to 150 Hz
Low cut-off frequency:0.01 Hz, 0.02 Hz, 0.16 Hz or 0.32 Hz (-3 dB limits)
High cut-off frequency:Configurable at 20 Hz, 40 Hz, 100 Hz or 150 Hz
Common mode rejection:>100 dB (with AC filter switched on)
Input impedance:>10MΩ @ 10 Hz, defibrillator protected
Patient leakage:<10 μA
Heart rate meter:30 to 300 BPM ±10% or ±5 BPM, whichever is greater.  
Start-up time:Less than 7 seconds

Environmental Specification:
Temperature Operating:5°C to 40°CTransport/storage:-15°C to 50°C
Humidity Operating:25% to 95% RH non-condensing;Transport/storage:25% to 95% RH non-condensing
Pressure Operating:700 to 1060 hPATransport/storage:500 to 1060 hPA

SZMEPLUS offer:
P/NDescriptionConnector Imagine
MPK017AIEC    Din3.0       4.7K resistance
Compatible Bosch One-Piece 10-Lead EKG Cable
 
MPK017BAHA   Din3.0      4.7K resistance
MPK017CIEC    Banana     4.7K resistance
MPK017DAHA   Banana    4.7K resistance
MPK017EIEC    Snap         4.7K resistance
MPK017FAHA   Snap        4.7K resistance
MPK017GIEC    Clip           4.7K resistance
MPK017HAHA   Clip          4.7K resistance

What's ECG/EKG?
The electrocardiogram (ECG or EKG) is a diagnostic tool that measures and records the electrical activity of the heart in exquisite detail. Interpretation of these details allows diagnosis of a wide range of heart conditions. These conditions would vary from minor to life threatening.

The term called electrocardiogram was introduced by Willem Einthoven in 1893 at a meeting of the Dutch Medical Society. In 1924, Einthoven received the Nobel Prize for his life's work in developing the ECG. The standard 12-lead ECG/EKG is used throughout the world in 1942.

Be called 12-lead ECG/EKG is because of it examines the electrical activity of the heart from 12 points of view.This is necessary ,because it can not provides a complete picture that what is going on if lack 1point(even 2 or 3 points).

Fully understand how an ECG/EKG reveals useful information about the condition of your heart requires, is a basis of understanding the anatomy (that is, the structure) and physiology (that is, the function) of the heart.

Why need ECG/EKG?
Heart problems can produce a wide array of symptoms.
the benefit of an ECG is, it may possible to tell whether these symptoms are being caused by heart problem or just mimicking one.

Therefore, enless your symptoms are explained by an illness, injury, or condition known to not effect the heart, otherwise an ECG measure will be generally done. 
Common symptoms that frequently require an ECG include the following: Chest pain or discomfort, Shortness of breath, Nausea, Weakness, Palpitations (rapid or pounding heartbeats or increased awareness of heart beating), Anxiety, Abdominal pain, Fainting (syncope)…
ECG often reveals a problem that is not primarily cardiac in nature. Examples are overdoses certain drugs (such as certain antidepressants) or electrolyte abnormalities (especially potassium).
If be about to have surgery with general anesthesia, you will need an ECG to detect any latent (silent) cardiac conditions that might worsen with the stresses of surgery and anesthesia.
People in any age who are in occupations that stress the heart (professional athletes or firefighters, for example) or involve public safety (commercial airline pilots, train conductors, and bus drivers) require ECGs as well.
Anyone aged 40 years or older should have an ECG done. This first, ECG serves as a screening tool to detect any cardiac problems and as a baseline for comparison of future ECGs.
A complete list of who should obtain an ECG, called Guidelines for ECG, is published by the Joint Committee of the AHA/ACC (American Heart Association/American College of Cardiology).

Leadwires size:
Compatible Bosch One-Piece 10-Lead EKG Cable
Compatible Bosch One-Piece 10-Lead EKG Cable
Compatible Bosch One-Piece 10-Lead EKG Cable
Compatible Bosch One-Piece 10-Lead EKG Cable
Compatible Bosch One-Piece 10-Lead EKG Cable






Payment: 

Compatible Bosch One-Piece 10-Lead EKG Cable



Transportation Methods:
Compatible Bosch One-Piece 10-Lead EKG Cable

warranty:
1, Reusable spo2 sensors are carried 12 months warranty to repair for free due to the quality problems since  ex-factory;
2, ECG cable and leadwires, spo2 adapter cable, EKG cable are carried 6 months for free (excluding disposable spo2 sensor), but including the misuse, negligence or accidents causing from the buyer.

Return:
     For all warranty return items, prior authorization to return merchandise must be obtained by contacting SZMEDPLUS. If the items are not covered under warranty, customer is responsible for all shipping fee 25%  restocking fee.

Contact information:
Company:Shenzhen Medplus Accessory Co.,LTD
Saler: Jenie Wei
 





 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours